PTU board from Meteo France (pressure, temperature, humidity).

Raw meteo data:

  • Pressure in ADC
  • Temperature in ADC
  • Humidity in micro-seconds (period of the input signal)

When using SEND_PTU flag, scaled pressure, temperature and humidity data are sent over telemetry with the PAYLOAD_FLOAT message (array of float). If scale factors and offset are not specified, raw values are sent (scale=1.0, offset=0).

When using LOG_PTU flag, raw pressure, temperature and humidity data are stored with raw gps data (position, speed, time, status). Field names and units are in the first line of the log file.

Example for airframe file

Add to your firmware section: This example contains all possible configuration options, not all of them are mandatory!

1 <module name="pwm_meas"/>
2 <module name="mf_ptu">
3  <configure name="ADC_PRESSURE" value="ADC_X" />
4  <configure name="ADC_TEMPERATURE" value="ADC_X" />
5  <configure name="PWM_INPUT_HUMIDITY" value="PWM_INPUTX" />
6 </module>

Module configuration options

Configure Options

  • name: ADC_PRESSURE value: ADC_X
    Description: Select ADC channel for pressure sensor
  • name: ADC_TEMPERATURE value: ADC_X
    Description: Select ADC channel for temperature sensor
  • name: PWM_INPUT_HUMIDITY value: PWM_INPUTX
    Description: Select PWM input channel for humidity sensor

Airframe file section

  • section name: MF_PTU
    • name PTU_POWER_GPIO value: GPIOX,GPIOYY
      Description: If defined, enable power by setting the specified GPIO to 1 at starup
    • name PTU_PRESSURE_OFFSET value: 0
      Description: Offset in ADC of the pressure sensor
    • name PTU_PRESSURE_SCALE value: 1.
      Description: Scale factor of the pressure sensor
    • name PTU_TEMPERATURE_OFFSET value: 0
      Description: Offset in ADC of the temperature sensor
    • name PTU_TEMPERATURE_SCALE value: 1.
      Description: Scale factor of the temperature sensor
    • name PTU_HUMIDITY_OFFSET value: 0
      Description: Offset in micro seconds of the humidity sensor
    • name PTU_HUMIDITY_SCALE value: 1.
      Description: Scale factor of the pressure sensor
    • name LOG_PTU value: TRUE|FALSE
      Description: Log data on SD card (ascii format, raw PTU data + GPS data)
    • name SEND_PTU value: TRU|FALSE
      Description: Send data over telemetry (PAYLOAD_FLOAT message, scaled PTU data)

Dependencies

Module functions

Init Functions

These initialization functions are called once on startup.

Periodic Functions

These functions are called periodically at the specified frequency from the module periodic loop.

  • mf_ptu_periodic()
    • Frequency in Hz: 10
    • Autorun: TRUE
      Periodic function automatically starts after init.

Files

Header Files

The following headers are automatically included in modules.h

Source Files

Raw mf_ptu.xml file:

<!DOCTYPE module SYSTEM "module.dtd">
<module name="mf_ptu" dir="meteo">
<doc>
<description>
PTU board from Meteo France (pressure, temperature, humidity).
Raw meteo data:
- Pressure in ADC
- Temperature in ADC
- Humidity in micro-seconds (period of the input signal)
When using SEND_PTU flag, scaled pressure, temperature and humidity data are sent over telemetry with the PAYLOAD_FLOAT message (array of float).
If scale factors and offset are not specified, raw values are sent (scale=1.0, offset=0).
When using LOG_PTU flag, raw pressure, temperature and humidity data are stored with raw gps data (position, speed, time, status).
Field names and units are in the first line of the log file.
</description>
<configure name="ADC_PRESSURE" value="ADC_X" description="Select ADC channel for pressure sensor"/>
<configure name="ADC_TEMPERATURE" value="ADC_X" description="Select ADC channel for temperature sensor"/>
<configure name="PWM_INPUT_HUMIDITY" value="PWM_INPUTX" description="Select PWM input channel for humidity sensor"/>
<section name="MF_PTU">
<define name="PTU_POWER_GPIO" value="GPIOX,GPIOYY" description="If defined, enable power by setting the specified GPIO to 1 at starup"/>
<define name="PTU_PRESSURE_OFFSET" value="0" description="Offset in ADC of the pressure sensor"/>
<define name="PTU_PRESSURE_SCALE" value="1." description="Scale factor of the pressure sensor"/>
<define name="PTU_TEMPERATURE_OFFSET" value="0" description="Offset in ADC of the temperature sensor"/>
<define name="PTU_TEMPERATURE_SCALE" value="1." description="Scale factor of the temperature sensor"/>
<define name="PTU_HUMIDITY_OFFSET" value="0" description="Offset in micro seconds of the humidity sensor"/>
<define name="PTU_HUMIDITY_SCALE" value="1." description="Scale factor of the pressure sensor"/>
<define name="LOG_PTU" value="TRUE|FALSE" description="Log data on SD card (ascii format, raw PTU data + GPS data)"/>
<define name="SEND_PTU" value="TRU|FALSE" description="Send data over telemetry (PAYLOAD_FLOAT message, scaled PTU data)"/>
</section>
</doc>
<depends>pwm_meas</depends>
<header>
<file name="mf_ptu.h"/>
</header>
<init fun="mf_ptu_init()"/>
<periodic fun="mf_ptu_periodic()" freq="10" autorun="TRUE"/>
<makefile target="ap">
<file name="mf_ptu.c"/>
<define name="ADC_CHANNEL_PRESSURE" value="$(ADC_PRESSURE)"/>
<define name="USE_$(ADC_PRESSURE)"/>
<define name="ADC_CHANNEL_TEMPERATURE" value="$(ADC_TEMPERATURE)"/>
<define name="USE_$(ADC_TEMPERATURE)"/>
<define name="PWM_INPUT_CHANNEL_HUMIDITY" value="$(PWM_INPUT_HUMIDITY)"/>
<define name="USE_$(PWM_INPUT_HUMIDITY)" value="PWM_PULSE_TYPE_ACTIVE_LOW"/>
</makefile>
</module>